he hey guys arpm here hope you're doing well having a really great day this video I want to talk about the 108 RTX 370s that I got I haven't received them yet but they are coming within the next week or two and so I need to mentally and also physically prepare to start running the power needed for those 108 307s which are going to be on this shelf right here I'm going to explain that all in this video mainly what I need to do to prepare to get the power up and running I want to talk about that in a second I want to First announce a giveaway of an ice server ks0 pro thank you to BP you guys may have saw the video last week I've already announced a giveaway uh I'm just making this video after the live stream we just did on Sunday congratulations to Mr ENT you have won a KS Z Pro good sir so please email me at contact redpanda mining.com go read the comment we replied to you on Mr greater good mining's video greater good mining what's up man BP thank you so much again guys we have eight more ksz Pros to give away I'm doing one each week so for this coming Sunday there will be a winner chosen for another ksz Pro I'm going to tell you guys how to participate it's very easy we're going to do a Discord only giveaway so link down below to join my Discord go to the announcements section announcement chat and you just have to read react hit the celebration confetti surprise emote on that giveaway for the ks zero Pro in the announcements section and then on Sunday the winner will be chosen okay automatically from the uh Discord bot so guys join up on my Discord good luck good luck to all of you and beep thank you again the gentleman who has graciously donated 14 ksz Pros he's given me 10 here to giveway and then Hawk chump change as well as Max voltage and the mining King are also giving away one BP has nothing to sell you he selflessly graciously and generously donated all of these to the crypto mining Community guys so good luck link down below to Discord a Yeti nice flag mind something I love your tag bro altered component overboard Tech geek of all trades I got blue moon mining there you guys I love your banners okay all right guys so I want to explain the 108 EVGA RTX 370s that I have coming in the next week or two and thank you to actually the mining King who has worked on packaging all of those the mining King has selflessly gave us time for packing all the 370s up from the gentleman whom I bought the 307s from so mining King thank you so much I owe you the world and you got to give me your Bitcoin address as well as everything else I'm going to send you a bunch of stuff so to explain here the 307s that I am going to be placing here in my this is where I live right you guys know this is where my a6r right right here and you all know I also have another mining area over here okay so like I said this is like my low power mining shelf area and I have my you know server WRA data rack there switches ubiquity stuff I have the 48 6600 XTS over here and I have a 400 amp service okay so I need to run more power so I have a bunch of 102 gauge cabling I don't know if I have enough but it's a good I would say a good 15 or 17 ft to this part of the Shelf here to the top of the shelf so my idea here is not only am I needing the power right but the gpus the 307s are going to be in all octo Miners and you guys know I have 10 of the GP Riser R8s right here as you guys know okay got 10 they're all in the boxes there I do have one already taken out just to show as a demonstration of how I'm eventually going to have all 10 filled up so it's going to have about 80 307s right I can only have about eight per R8 so I have 80 at the top row and then for the rest of the 307s I I'm going to have to figure out yeah I should be able to fit them at the bottom row here uh I do have some more s cases at my other location they're not R8s so my OCD may may kill me a bit there but that's okay that's okay so you guys understand how I'm going to lay out the gpus okay on this metal shelf and I'll have it in server cases then as well in terms of air flow maybe or like heat extraction I obviously have a window here and I do have a I think this is a 22in exhaust fan and this is just a simple Vore branded one I got off Amazon I'll have a link down below but this is uh just a variable one which does come with a variable controller here uh that I'm going to install on the on the side here I do have a 120 volt power I already ran myself and as well I do have uh Network at the top I already ran myself here for this rack then all the pdus I bought a bunch of these from Alibaba okay these are the 30 amp 240 volt power distribution units okay it has uh eight of these c14 plugs and I got three of the C20 uh c19 plugs here it does have a digital meter as well but at the other side of the pdu I'm also going to have the meter box meters as well digital meters along with the you know l630r okay receptical plugs are going to be in each of these four so yeah I want to run four circuits in for this shelf now the biggest thing is where the heck am I going to have those four circuits and I'm going to have to run those in the next I don't know next week here maybe right after this video I'm pretty determined and motivated now uh to get it going cuz I'm going to have all these gpus coming and I need to have the power infrastructure up before I can get them all plugged in right as you all know I do have another mining location area with a bunch of OCTA miners a server wall there you guys know and uh I have no more power capacity there essentially so my plan here is to obviously I need to run the 102 gauge cabling here thank you to Mr Luke puges for sending me a bunch of 102 cable this is amazing man you also helped with the other cabling I did for my Asic wall as well over there but man this cabling it's working out great for my other as6 that are on this 400 amp service here I have 2X 200 amp circuit panels here so I wanted to talk about how should I distribute the power okay as I'm already pretty much maxed out in Breakers I do already have let's see one two three okay I have three four five sorry I have five 240 volt 30 amp Breakers already in here that are not populated I already have these three which are populated for my A6 okay the three over here as you all know right I did this myself it was a lot of work man I am never going to go through a 90 ever again that was just just brutal but I made it work with the meter boxes here and uh yeah 3 30m circuits how I have it like this with EMT connectors all that stuff uh with the meter box boxes okay so you guys know how I'm probably going to have it set up just like for the gpus so same idea I will have yeah like EMT connectors and actually I'm thinking to make it easier for myself uh for wiring these four circuits I'm was initially thinking of putting it where the veteran minor cables are uh veteran minor flag is so I was going to have all four meter boxes here and then have a singular 1in EMT going up here and then doing a 90 and then going up there but I realized that's probably going to be a lot of work in a way and so my idea is or my plan is to basically have the meter boxes all in line with each other in a straight line I'm going to have them straight in a row at the top here okay so then I'll just be able to do a 1 in EMT hopefully on the right there just going out here and then straight into a first box and then I'll have EMT connectors connecting each one going into every single meter box it'll just be like up there if that makes sense hopefully that makes a bit of sense and so that I don't have to do a 90 down the wall and then do more wiring and uh 90 down here it just it's such a pain the a trying to get the uh the 102 gauge cabling which I do cut the uh the orange stuff off when I go into the EMT just to keep it to code because uh yeah this is uh normally uh RX doesn't go into EMT from from what I gather I'm not an electrician I'm not trying to give advice here I'm just just stating uh what I'm doing so just don't follow what I'm doing always have an electrician certified electrician to do your electrical work always so yeah going to cut this up and then it turns into like I hhn wiring and that's just going to go into the EMT by itself so I'm going to cut off the just the orange wrap and then uh I can put these wires into the uh into the EMT no problem so now let's talk about how the breakers d distribution here so I do have another two spare 30m 240 volt circuits here okay and then everything else is filled up on this circuit panel then I already talked about this panel I do have five extra here but three are already populated here uh for the as6 so I recently just learned that if I use about 6 amps at 24 amp each okay in terms of load 80% rule that I should be able to hit that uh hit that uh medium general service rate that I can achieve which is about 7.5 cents USD so if I can utilize evenly at least three circuits per uh circuit panel here then I can achieve that electrical rate that that load I have to use concurrently every day so I think that's about 150 160 amps or something like that I think minimum like 35 kilowatt per hour and so another thing that I want to be cognizant of is the load I currently have on the circuit panels okay so most of my house okay upstairs I have a bunch of 20m circuits all right really not a lot of them are being used granted I was using a lot of these for heating my house upstairs okay like you guys know my like little gold shell miners those little heaters Sometimes some GP rigs are on some of these but summer's coming so probably going to be turning most of those off so I'm not going to be using a lot of these 20 amp circuits which are in every single room in my house upstairs so going now into the rest of the panel which are the 30 amp circuits okay so I have three that are for the as6 right and so now I have five extra that are not being used yet that are not wired in with any 10 gauge cabling right so I have five free here so I'm thinking that for the four that I need the four circuits I need for the the GPU rack okay I'm thinking of adding three Okay so three here then I'm going to have two spares so if I have these at 24 amps load each or 80% that's going to be what 70 to 75 amps load right respectively and then these ones are pretty much at the 80% rule already so combin I'll be about 150 amps usage if I were to max out each of these okay and that means yeah the rest of the circuits I'm not going to be really I'm not really using much but then okay so you understand this that's some my thought process here for having uh running three so I need one more circuit and that's what I'm thinking about running on here okay I have two 30m circuits not populated yet so I'm thinking of adding the last 240 volt 30 amp circuit for the GPU rack uh for the 307s here so then the rest of my rack is already pretty populated I have like the range the dryer um my EV charger Tesla charger right and uh my server rack is here along with the 48 6600 XTS on this one as well and then my low power rack that's also this whole rack here 30 amp 240 volt is also here and I also have another one that's populated for my uh test bench right this is where I test out my as6 and stuff on this area here as you all know so I got a lot of power already pretty much being utilized on this first uh circuit panel so I was thinking of adding another two here but I just realized that you know most of my house services are being run on this panel like my sewer stuff my you know basement stuff uh circuits for the lights upstairs and everything you know I don't think adding it up in my head you guys can probably do that as well it's it's I'm going to have to say it's it's getting pretty it's getting pretty maxed already dryer range EV charger the 3 30 amp circuit for my mining again like I said so really we got I think currently I am already using about 100 amps maybe more already with the 3 30m circuits and uh everything else right just just just to be safe cuz you know if I plug in my car or you know the dryer turns on or my wife is cooking or something that's going to be a good 50 60 amps already and so if I'm already pulling like a good 70 amps already from that and and that and my test bench area with an Asic sometimes then yeah this rack is going to get pretty loaded this 200 amp circuit panel is going to get pretty loaded so I'm thinking one 30m circuit on this one and then I will do three 30m circuits on this one what do you guys think about that let me know down below installation wise I I mean I I've done my Asic my Asic one before that was actually a lot of work wiring it in myself you know nailing it up on the uh the The Columns here and just all the way to my as6 shelf over there that was seriously a lot of work and with also the 1in EMT going through the subar there going down there that was a lot of work and then wiring it in there so I'm going to have to do pretty much the exact same thing but is going to be much shorter to here that's that's what I'm thinking right now so it' be a lot easier I just plug in the pdus up there right and then they should all go into this shelf here and then I can power all my gpus uh here okay let me know what you guys think about that I'm going to start working on this right now it's going to be a lot of work I need to go to Home Depot and yeah I need to buy more uh EMT connectors actually I need to buy uh one EMT 1 in EMT just just a short run from there to there and that's really all the EMT I need but then I need all the connectors as well I already have I got a hammer I got that I got my pliers I got my I got I think I got all the tools yeah going to be doing that guys in the next week here I may I'm just thinking about it now I may not have videos coming out cuz I do want to work on this and get it right I'm going to spend a lot of time making sure I'm going to put this in right the same thing I did with my other my other 240 volt circuits it took me a good like I don't know a week to get that installed but yeah okay you guys let me know your thoughts thank you guys for watching and uh I'll keep you guys updated hopefully I can get this done so I may Vlog you know installing the wire installing all the circuits maybe we'll see uh but I'm going to go to Home Depot now and get all the stuff I needed okay I'll see you on the next one don't forget to join Discord for the ks Z Pro all right for one of these winner will be chosen on Sunday good luck my friends good luck have a good one everyone thanks for watching peace out peace out